Blueway DC Inverter Rooftop Package Air Conditioner for Sinus Area are commercial packaged HVAC units engineered for aedificia flexibilia, industria efficacia, et utilia calefactione et refrigeratione indigent. Available from5 ad 60 talenta (25-241 kW)facultatem refrigerandi, plena technologia dc inverto adhibent premium volumen Compressors eripere usque adXL% industria peculiversus fixum-celeritate turmas sub onere condicionum, cum temperatura definita moderatio ±0,5°C.
Product Details
| Product Name | DC Inverter Rooftop Package Aeris Conditioner ad sinus Area |
|---|---|
| Munus | Commercial aedificium refrigerandi & calefaciendi; nova caeli evacuatione libitum (WFI) |
| Capacitas refrigeratio | 25 – 241 kW (5 – 60 tons, secundum exemplar) |
| Calefaciens capacitatem | 30 – 280 kW (caloris sentinam exempla) |
| EER / COP | Usque ad 3.8 / 4.2 (DC inverter, condiciones onus partis) |
| Compressor | Magnum volumen compressor (1, 2, vel 4 unitates per exemplar) |
| Refrigerant | R410a - nulla ODP, eco-amica |
| Type CERAULA | Centrifuga - pressus static 100-850 Pa |
| Controller | LCD tactus screen cum auto-diagnostica functionis |
| Warranty | 1 annus (plenus unitas) / 3 years (compressor) |
| Applications | Scholae, scruta, officia, facultates medicas, systemata DOAS |
Product Overview
Blueway Sina DC Inverter Tectum Package Aeris Conditioner ad sinus Areain specie machinata ad aedificia commercialia quae requirunt solutiones flexibiles, industria efficientes, solutiones certas HVAC. Cum technologia plena DC invertis ac compressoribus premium volumen, hae unitates liberanteximia parte-onus efficientiam- in discrimine utilia aedificia cum variabilis negotium et refrigerationem / calefactio postulata. Tectum configuratione liberat pretiosum amet pavimento spatio dum facilem aditum praebens victum.
Clavis Applications - Proven in Commercial Environments
- Scholae & academiae— commoda Integer et auditoria cum quiete, efficiente operatione.
- Retail stores & shopping malls- temperatura certa moderatio pro Lorem commodo et industria sumptus procuratio.
- Munus aedificia— Incolatorio constanti pro fructibus possessoris, cum nova aeris evacuatione ad libitum.
- Facultates medicae— temperatura subtilis et humiditas temperantiae ad patientiam consolationis et armorum tutelam.
- Aeris Systems Outdoor dedicated (DOAS)- 100% nova caeli preconditioning ad meliorem amet orci (IAQ).
Key Features
- Lata productum range- 5 ad 60 talenta, parva aedificia commercialia per magnas complexa scruta tegens.
- technologia plena DC inverter- variabilis celeritas operationis tradit usque ad 40% compendia navitatis cum unitatibus fixum-celeritate comparatis (ex conditionibus AHRI parte oneris innititur), cum certa temperatura moderatio ±0,5°C.
- Magnum volumen compressor notam- praestantia observantia, diuturnitas, et humilis vibratio, subnixum aCompressor III annos warantum(I annus pro unitate integra).
- Eco amica R410a refrigerandi- nulla ozone deperditionem potentiale (ODP), obsecundantem cum F-Gas ordinationes et signa environmental global.
- Intelligens LCD tactus screencum auto-diagnostica functione - real-time culpa summis et ad libitum remota vigilantia per RS485/Modbus.
- Applications versatiles- specimen scholarum, thesaurorum venditorum, officiorum aedificiorum, facultatum medicorum, et systematum aereorum fori dedicatum (DOAS).
- Flexibile configuratione- refrigeratio-tantum, calor sentinae (calefactio + refrigeratio), vel calor sentinam + recens aer VENTILATIO (WFI) bene.
- Proven semita record- Blueway tecto unitates explicatae sunt in terminis inceptis comprehendoUniversitas ShenzhenetCapulum Hotelsdemonstrans constantiam in ambitibus commercialibus exigendis.
Products Specification - BHP Series Hardware Platform Reference
| Exemplar | BHP (Platform) | 15 | 20 | 25 | 30 | 40 | 50 | 60 | 80 | 100 | 120 | 160 | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Potestas Supple | V/P/Hz | 380-415/3/50 vel 208-230/3/60 | |||||||||||
| Output (Rotform Reference) | Refrigerium | kW/h | 25 | 33 | 41 | 51 | 65 | 82 | 97 | 131 | 163 | 192 | 241 |
| Heating | kW/h | 30 | 39 | 47 | 60 | 78 | 106 | 128 | 170 | 214 | 243 | 280 | |
| Dehumidification capacitas | Kg/h | 17 | 22 | 26 | 33 | 43 | 51 | 62 | 84 | 102 | 122 | 160 | |
| Rated Airflow | m³ @ 300Pa | 4000 | 5000 | 6000 | 7500 | 9000 | 11000 | 13000 | 16600 | 21000 | 25000 | 32000 | |
| Blower | Qty | Nos. | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 |
| Type | — | Centrifuga | |||||||||||
| Vestibulum pressura range | Pa | 100-500 | 100-500 | 100-500 | 100-500 | 100-850 | 100-850 | 100-850 | 100-850 | 100-850 | 100-850 | 100-850 | |
| Potentia input | KW | 1.5 | 1.5 | 2.2 | 2.2 | 3.5 | 4 | 5.5 | 6 | 7 | 7.5 | 11 | |
| Compressor | Qty | Nos. | 1 | 1 | 1 | 2 | 2 | 2 | 2 | 2 vel 4 | 2 vel 4 | 2 vel 4 | 2 vel 4 |
| Type | — | volumen | |||||||||||
| Potentia input | KW | 5.5 | 7 | 8.5 | 5.4 | 7 | 8.5 | 11 | 7 or 13 | 8.5 vel 16.5 | 11 vel 22 | 13 vel 25 | |
| Indoor Main Unit Pondus | Kg | 500 | 800 | 900 | 1200 | 1500 | 1650 | 1850 | 2200 | 2500 | 2700 | 3300 | |
Notae:
- Haec mensa repraesentat BHP seriem suggestum mechanicum — dimensiones, blower, et compressor architectura per multiplices familiae productum Blueway.
- ForDC Inverter Rooftop Air Conditionerfinalis notitia exsecutionis (EER/COP, facultatem exactam apud ambientes specificos, et optimizationem static pressionis), contactum machinationis nostrae turmam pro delectu exstent.
- Omnes unitates recipiunt plenam functionis probationem in lab nostra ISO17025 adprobata ante traditionem. Testium testimoniales per Vide numerum eduntur.
Comitatu Information - Global HVAC Solutions Providentem
BLUEWAYanno 1993 clara visione condita est;"Fac vitam commodam!"Cum super XXX annos industriae experientiam, societas famam terrarum in calefactione et refrigeratione liquida meruit systemata servientes clientibus per Europam, Orientem Medium, Asiam Meridionalem et Americam.
Vestibulum Hub & Innovation:Anno 2007, Blueway vestibulum subsidiarium suum constituit basis in Shunde, Foshan, China - opportuna in corde Guangdong provectus vestibulum ecosystem. Haec facilitas R&D integrat, productionem et qualitatem certitudinis sub uno tecto, ut celeri solutiones prototypas et nativas pro applicationibus commercialibus et industrialibus.
Diversa Product Portfolio:Blueway praebet comprehensive range HVAC productorum, comprehendotectum caeli conditioners, commercial/lux commercial aer conditioners, air-source water . chillers, heating/frigidatio calor soleatus, aqua calida calor soleatus, lacus calor soleatus, aqua-ad-aqua calor soleatus, unitates aeris tractantes (AHU), recentes aeris unitates, et systemata VRF — modo energiae salutaris integratae solutiones pro aedificiis commercialibus, complexionibus residentialibus et ambitus industriales specialioribus.
Qualitas certificationum:Blueway tenet ISO9001 (Quality Management) et ISO14001 (Environmental Management) certificaciones ex SGS (numeri testimonium available postulante), cum CE, ErP A+, et ErP A++ de industria efficientiae certificationum TUV - independenter convalescit qualitatis causa mercatus globalis.
Historia - 30+ Annos Commercial HVAC Excellentiae
-
1993
Notam Blueway in Australia conditam, industriam HVAC globalem ingrediens cum umbilico ad systemata calefactionis et refrigerationis innovat.
-
2007
Sinae basim fabricandi in Shunde, Foshan - integrant technologiam Australiae cum efficientia fabricandi Sinensi.
-
2008
Calorem sentinam et condiciones aeris in terris Europaeis productos educendi incepit, famam qualitatis et constantiae celeriter aedificans.
-
2011
Factus est particeps officialis forUniversitas Shenzhen(Ludis global eventu) et pro elit qualifiedCapulum Hotels- demonstrandi facultatem Blueway in magnis inceptis commercialibus HVAC.
-
2013
R32 EVI + Inverter calor sentinam consecutus ErP A ++ certificatorium ex TUV - industriae industria efficientis cognitio.
-
2020
Dilatata productio ad AHU, Aeris recentis unitates, VRF, aliaque HVAC producta relatas - solutiones climatis integram commercialem aedificationem offerens.
Cooperantem sociis
Commoda nostra - Quid Commercial Socii elige Blueway
USUS
30+ Yearsin HVAC industriam
Fundavit 1993, educendo ad 40+ regiones
COMMODUM
Vestibulum hendreritin Shunde, China
OEM / OBM / ODM facultates
Tectum ACnativus solutiones
SERVITIUM
24-Hour Responsiocommitment
Post-Sales firmamentum dedicated
Consilium technicum praesto
Forum
30+ R&D Engineers
Enabling nativus HVAC solutiones pro inceptis commercialibus
QUALITAS'
ISO9001 & ISO14001 by SGS
Plena operational probatio in omnibus unit
ISO17025-calibrated lab verificationis
CERTIFICATIONS
CE, ErP A+, A ++ TUV
Obsequium global signa
Environmentally author
Project References - Real-World Commercial HVAC Installations
Causa Study 1: Hilton Hotels - Premium Hospitalitas Clima Control
Provocare:Proprietas Hilton quaesivit solutionem HVAC industriae efficientis ad piscinam umbraticam et ad otium areas adjacentes. Ratio necessaria est ad severam humiditatem gradus (infra 60% RH) conservandos, ne corrosio structurae et consolationis hospitem curet, dum simul reducendo impensas perficiendas.
Solutio:Blueway explicavit nativum DC Inverter Rooftop Aeris Conditioner cum WFI (novali aeris evacuatione) functionality, cum dedicata dehumidificationis serie integrata. Unitas configurata est ad operandum sub arduis ambientium oneribus sustinens susurrans quietam operationem ne turbaret gazofilacia hospitum.
Consequuntur:Systema emendate post institutionem operavit, stabilis humiditatem servans ad 55%-58% RH et assequendam.XXVIII% anno industria peculiceleritas ratio certa comparari ad priorem. Hilton cum idoneis Blueway ut socium probatum pro pluribus locis habet.
Case Study 2: Universiade Shenzhen - Large-Scale Public Venue HVAC
Provocare:In MMXI Universiade imperium climatis requirebat ad facilitates multiplices magnarum volubilium cum occupando valde variabili (ab inanis ad plenam capacitatem intra minuta). Systema HVAC statim respondere oportuit, servato energia efficientiae per perfiles onus fluctuantis.
Solutio:Blueway praebebat multi-unitatem Tecti AC configurationis featurarum plenarum DC invertorum compressorum et Modbus integrarum BMS moderantium, ut reale tempus onus tracking ac scenicum modulationis facultatem praebeat.
Consequuntur:Systema consolatoria condiciones amet in eventu, cumapicem onus efficientiam excedens AHRI baseline per XXXIV%. Venue pergit apparatu Blueway ut operationes permanentes.
Additional incepta includit Hong Kong AGASO Club Conghua Venue, Fujian Provinciale Natans Centrum, Yancheng Vienna International Hotel, and Shunde OCT Swan Castle — all reflecting Blueway's engineering peritia et industria ad mensurabile perficiendum.
FAQ — Rooftop Air Conditioner Technical Questions
- Quae sunt amplitudines paratae pro tecto acs Blueway, et magnas scruta complexum tractare possunt?
- Blueway tecto AC unitates available in lato range ex5 to 60 tons(circa 25-241 kW facultatem refrigerandi). Utrum condicionibus es a 2.000 m² in promptuarium vel a 15000 m² mall, exemplum habemus vicium. Nostra machinalis quadrigis potest etiam multi-unitatis configurationes praebere pro amplioribus complexibus cum constructis-in redundantia.
- Quantum possum actu salvare de industria legum cum DC inverto technologia?
- Sub condiciones typicae partis oneris (quae supra 70% horas operandi in aedificiis commercialibus repraesentant), systema invertum DC attingitad XL% industria peculifixum-traditional celeritas comparari augent. Ex actuali Hilton deversorium project notitia, salutaris annui mensuratus est28%in operationibus realibus mundi - transferendo ad significantes sumptus reductionem super vitalem unitatis.
- Possumne tectum AC integrare cum structuris automation systematis existentibus?
- Absolute. Omnes Blueway tecto unitates supportRS485 / Modbus communicationis protocolut vexillum. Hoc permittit inconsutilem integrationem cum suggestis BMS maioribus (Siemens, Honeywell, Schneider, etc.) ut vigilantia centralised, culpa diagnosis remota, et optimisationi perficiendi automated.
- Num Blueway project speciales customizationem pro culminibus unitatibus providere?
- Ita — omne Blueway culmen AC configurabile est. Optiones refrigerationis solum includunt, sentinam caloris cum cyclo contrario, WFI recens aeris evacuatione, electrici vel aquae calidae recalcitatione, aspirantes summus statorum (usque ad 850 Pa), et consuetudo colorum pingunt. Offerimus etiam OEM/ODM notam pro magnis-volumis sociis.
- Quid praestat Blueway et tegitur?
- Blueway comprehensive praebetI-annus warantum ad integram unitatemet extenso3-annus warantizatio speciatim ad librum compressor. Omnes petitiones warantiae per network ministerium nostrum globali discursum cum responsalitate 24-horarum.
- Quomodo facit Blueway ut productum qualitas apud naviculas?
- Omnis unitas patitur severumminimum LXXII hora continua operational testin officina nostra ISO17025 calibrata. Haec includit sanationem plenam et partem oneris perficiendi, Leak probatio, vibratio analysis, et strepitus graduum verificationis. Quaelibet unitas editur testimonium singulare testimonium cum deprauabili serial numero — cum qualitatis perfectae perspicuitatis.
- Quid est proprium plumbi tempus, et naves internationales sustentas?
- Latin productio plumbi tempus est proximeXXXV opus diebuspost recepcionem solucionis et technica ultima probat. Blueway exportationes ad per 40 regiones per orbem plenas naves et logisticas sustentationes, incluso coordinationis et consuetudinum documentorum subsidia onerantia.